Personal Noise Dosimeter
Technical Specifications

The default settings used by the ER-200 for calculation of noise dose are consistent with ANSI S1.25–1991 (R2002) Specification for Personal Noise Dosimeters.

Calibration Accuracy: ±2 dB
Dose Calculation Criteria:
      Exchange Rate: 3 dB
      Criterion Level: 85 dB
      Threshold Level: 75 dB
      Criterion Time: 8 hours
      Frequency Weighting: A
      Response: Slow
Temperature Range of Operation: -10°C to 45°C (14°F to 113°F)
Omni-directional Microphone: Flat from 100 Hz to 15 kHz
Earphone Monitor Jack (2.5 mm): 10 mV (-40 dB re 1V) corresponds to 94 dB SPL ±1 dB at 1 kHz
Frequency Weighting For Earphone Monitoring: Same as microphone (A)
Power Supply: Three AAAA batteries
RMS Detector: Dynamic range 60 dB (70 to 130 dB)
Battery Life: > 250 hours continuous use