Personal Noise Dosimeter
Interpreting Results

Interpreting Results — Normal Mode
LED Dose % Risk Factor Hearing Protection Needed
green (slow flash) < 25% No risk of hearing loss NO
green (fast flash) 25% No risk of hearing loss NO
green 50% 1/2 daily dose reached NO
yellow 100% Limit of permissible exposure YES
red 200% 2x allowable daily dose YES
Muffled hearing and ringing in the ears are likely after unprotected exposure.
red 400% 4x allowable daily dose YES
red 1600% 16x allowable daily dose YES
red 3200% 32x allowable daily dose YES

Interpreting Results — Quick Check (2-minute test)
If the LED color is: The estimated dose per hour is: The estimated dose per 8 hours is:
green (slow flash) < 25% < 200%
green (fast flash) 25% 200%
green 50% 400%
yellow 100% 800%
red 200% 1600%
red 400% 3200%
red 1600%  
red 3200%  

Time to Reach 100% Dose
  % Dose
Per Hour
% Dose
8 Hours
  Time (hours) to Reach 100% Dose
Level (dBA) No EP ER-9 ER-15 ER-25 ER-20
85 <25 (12.5) 100 8 24 24 24 24
88 25 200 4 24 24 24 24
91 50 400 2 16 24 24 24
94 100 800 1 8 24 24 24
97 200 1600 30 min 4 16 24 24
100 400 3200 15 min 2 8 24 22 (est)
103 800 6400 7.5 min 1 4 24 14 (est)
106 1600 12,800 3.8 min 30 min 2 20 (est) 7 (est)
109 3200 25,600 1.9 min 15 min 1 10 (est) 3.5 (est)

Copyright © 2000 - 2012, Etymotic Research, Inc.